Abstract
Background
For primary angle-closure and angle-closure glaucoma, the fact that refractive error sometimes deviates from predictions after intraocular lens (IOL) implantation is familiar to cataract surgeons. Since controversy remains in the accuracy of IOL power calculation formulas, both traditional and network meta-analysis on formula accuracy were conducted in patients with primary angle-closure conditions.
Methods
A comprehensive literature search was conducted through Aug 2022, focusing on studies on intraocular lens power calculation in primary angle-closure (PAC) and primary angle-closure glaucoma (PACG). A systemic review and network meta-analysis was performed. Quality of studies were assessed. Primary outcomes were the mean absolute errors (MAE) and the percentages of eyes with a prediction error within ±0.50 diopiters (D) or ±1.00 D (% ±0.50/1.00 D) by different formulas.
Results
Six retrospective studies involving 419 eyes and 8 formulas (Barrett Universal II, Kane, SRK/T, Hoffer Q, Haigis, Holladay I, RBF 3.0 and LSF) were included. SRK/T was used as a reference as it had been investigated in all the studies included. Direct comparison showed that none of the involved formula outperformed or was defeated by SRK/T significantly in terms of either MAE or % ±0.50/1.00 D (all P>0.05). Network comparison and ranking possibilities disclosed BUII, Kane, RBF 3.0 with statistically insignificant advantage. No significant publication bias was detected by network funnel plot.
Conclusions
No absolute advantage was disclosed among the formulas involved in this study for PAC/PACG eyes. Further carefully designed studies are warranted to evaluate IOL calculation formulae in this target population.
Trail registration
Registration: PROSEPRO ID: CRD42022326541.
Funder
Shanghai Municipal Health Commission
Clinical Research Plan of SHDC
National Key Research and Development Program of China
the State Key Program of National Natural Science Foundation of China
National Natural Science Foundation of China
Publisher
Public Library of Science (PLoS)
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献