Accuracy and repeatability of the Microsoft Azure Kinect for clinical measurement of motor function

Author:

Bertram JohannesORCID,Krüger Theresa,Röhling Hanna Marie,Jelusic Ante,Mansow-Model Sebastian,Schniepp Roman,Wuehr Max,Otte KarenORCID

Abstract

Quantitative assessment of motor function is increasingly applied in fall risk stratification, diagnosis, and disease monitoring of neuro-geriatric disorders of balance and gait. Its broad application, however, demands for low-cost and easy to use solutions that facilitate high-quality assessment outside laboratory settings. In this study, we validated in 30 healthy adults (12 female, age: 32.5 [22 – 62] years) the performance and accuracy of the latest generation of the Microsoft RGB-D camera, i.e., Azure Kinect (AK), in tracking body motion and providing estimates of clinical measures that characterise static posture, postural transitions, and locomotor function. The accuracy and repeatability of AK recordings was validated with a clinical reference standard multi-camera motion capture system (Qualisys) and compared to its predecessor Kinect version 2 (K2). Motion signal quality was evaluated by Pearson’s correlation and signal-to-noise ratios while the accuracy of estimated clinical parameters was described by absolute and relative agreement based on intraclass correlation coefficients. The accuracy of AK-based body motion signals was moderate to excellent (RMSE 89 to 20 mm) and depended on the dimension of motion (highest for anterior-posterior dimension), the body region (highest for wrists and elbows, lowest for ankles and feet), and the specific motor task (highest for stand up and sit down, lowest for quiet standing). Most derived clinical parameters showed good to excellent accuracy (r .84 to .99) and repeatability (ICC(1,1) .55 to .94). The overall performance and limitations of body tracking by AK were comparable to its predecessor K2 in a cohort of young healthy adults. The observed accuracy and repeatability of AK-based evaluation of motor function indicate the potential for a broad application of high-quality and long-term monitoring of balance and gait in different non-specialised environments such as medical practices, nursing homes or community centres.

Funder

Bundesministerium für Bildung, Wissenschaft, Forschung und Technologie

Else Kröner-Fresenius-Stiftung

Gemeinsame Bundesausschuss

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3