Evaluation of superficial xenograft volume estimation by ultrasound and caliper against MRI in a longitudinal pre-clinical radiotherapeutic setting

Author:

Roth DanielORCID,Safi Marcella,Vilhelmsson Timmermand Oskar,Sereti EvangeliaORCID,Molendowska MalwinaORCID,Gottschalk Michael,Bjartell Anders,Ceberg Crister,Szczepankiewicz FilipORCID,Strand JoannaORCID

Abstract

Background Accurate tumor volume estimation is important for evaluating the response to radionuclide therapy and external beam radiotherapy as well as to other pharmaceuticals. A common method for monitoring the growth of subcutaneous tumors in pre-clinical models and assessing the treatment response is to measure the tumor length and width by external calipers to estimate its volume. This procedure relies on an assumption of a spheroidal tumor shape wherein the tumor depth equals the width and can yield considerably inaccuracies. Ultrasound imaging is a non-invasive technique that can measure all three axes of the tumor and might be an alternative to caliper measurement with potentially greater accuracy and comparable ease-of-use and throughput. Both 2D and 3D ultrasound imaging are possible, the former offering short scan times without the need for anesthesia and heating—valuable factors for longitudinal studies in large animal cohorts. Nevertheless, tumor volume estimation accuracy by 2D ultrasound imaging has seen limited investigation. In this study we have evaluated the accuracy of tumor volume estimation by caliper and 2D ultrasound with comparisons to reference measurements by magnetic resonance imaging (MRI) in a pre-clinical model of prostate cancer treated with either external beam radiotherapy, radionuclide therapy, or no treatment. Results Tumor volumes were measured longitudinally in 29 mice by caliper, ultrasound, and MRI before and after external beam radiotherapy, [177Lu]Lu-PSMA-617 radionuclide therapy, or no treatment. Caliper measurements had a marked bias, overestimating the tumor volumes by a median of 150% compared to MRI. Ultrasound measurements were markedly more accurate, with a median bias of -21% compared to MRI. Conclusion Ultrasound imaging is a reliable and accurate method for tumor volume estimation in pre-clinical models of radiotherapy, whereas caliper measurements are prone to overestimation.

Funder

Fru Berta Kamprads Stiftelse

Cancerfonden

Vetenskapsrådet

Publisher

Public Library of Science (PLoS)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3