Effects of low versus high inspired oxygen fraction on myocardial injury after transcatheter aortic valve implantation: A randomized clinical trial

Author:

Cho Youn JoungORCID,Hyeon CheunORCID,Nam Karam,Lee Seohee,Ju Jae-Woo,Kang Jeehoon,Han Jung-Kyu,Kim Hyo-Soo,Jeon YunseokORCID

Abstract

Background Oxygen therapy is used in various clinical situation, but its clinical outcomes are inconsistent. The relationship between the fraction of inspired oxygen (FIO2) during transcatheter aortic valve implantation (TAVI) and clinical outcomes has not been well studied. We investigated the association of FIO2 (low vs. high) and myocardial injury in patients undergoing TAVI. Methods Adults undergoing transfemoral TAVI under general anesthesia were randomly assigned to receive FIO2 0.3 or 0.8 during procedure. The primary outcome was the area under the curve (AUC) for high-sensitivity cardiac troponin I (hs-cTnI) during the first 72 h following TAVI. Secondary outcomes included the AUC for postprocedural creatine kinase-myocardial band (CK-MB), acute kidney injury and recovery, conduction abnormalities, pacemaker implantation, stroke, myocardial infarction, and in-hospital mortality. Results Between October 2017 and April 2022, 72 patients were randomized and 62 were included in the final analysis (n = 31 per group). The median (IQR) AUC for hs-cTnI in the first 72 h was 42.66 (24.82–65.44) and 71.96 (35.38–116.34) h·ng/mL in the FIO2 0.3 and 0.8 groups, respectively (p = 0.066). The AUC for CK-MB in the first 72 h was 257.6 (155.6–322.0) and 342.2 (195.4–485.2) h·ng/mL in the FIO2 0.3 and 0.8 groups, respectively (p = 0.132). Acute kidney recovery, defined as an increase in the estimated glomerular filtration rate ≥ 25% of baseline in 48 h, was more common in the FIO2 0.3 group (65% vs. 39%, p = 0.042). Other clinical outcomes were comparable between the groups. Conclusions The FIO2 level did not have a significant effect on periprocedural myocardial injury following TAVI. However, considering the marginal results, a benefit of low FIO2 during TAVI could not be ruled out.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3