Abstract
Objectives
Recording and reproducing mandibular movements have been of key importance in the practice of dentistry for over a century. Recently, it has become possible to use digital technologies for these tasks. This study presents a preliminary method to try to identify the mandibular instantaneous centres of rotation based solely on intraoral scanners.
Methods
The dentitions of four participants were scanned, multiple inter-occlusal registrations and buccal scans were performed in closed and opened positions. Blender software was used to align the meshes during the post-scan digital workflow. Bite alignment accuracy was assessed and then improved with a strict exclusion protocol. An automated algorithm was used to find rotations between closed stage and open stage meshes.
Results
Our exclusion protocol reduced the bite alignment error significantly (p = 0.001) and the root-mean-square error value of the meshes decreased from 0.09 mm (SD = 0.15) to 0.03 mm (SD = 0.017). However, the remaining translational error caused an unexpectedly large shift in the axis of rotation (mean = 1.35 mm, SD = 0.77) with a 41.83: 1 ratio. As found in other studies, our results showed even a small amount of error during registration can shift the axis of rotation a large amount. This phenomenon will compromise the results of common pantographic methods which assume a rotation axis of the condyle. It also adds valuable information to the concept of instantaneous centers of rotation by revealing their true characteristics.
Funder
University of Szeged Open Access Fund
Publisher
Public Library of Science (PLoS)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献