The Effect of Dry and Wet Bulb Temperature Variation on the Performance of the Indirect Evaporative Cooler

Author:

Zaidan Maki1,Abed Fayadh1,Farhad Ali1

Affiliation:

1. Mechanical Engineering Department, Tikrit University, Salahuddin, Iraq

Abstract

The research is about designing and building up an evaporative cooling system, working by two- stages evaporative cooling system using outer air (pure air). The system is founded by designing and making a heat exchanger of orthogonal flow from Aluminum sheets of (30*60*40) cm, which represents the first stage of the system (indirect stage). The second stage (direct stage) of the system is represented by making an equipment of air washing (cylindrical) with (45 height, 60 width, 3 thickness) cm. The cooling system pulls outer air by a Centrifugal fan. The air passes through the heat exchanger pipes to be cooled tangibly (without moistening). Then it goes over the equipment of air washing to be cooled and cools the specified space. Computer software was designed by FORTRAN Language (FORTRAN 90) to predict the evaporative air cooler performance to know the proper environmental and design conditions of the system. Some variables were made to study their effect on the thermal performance of the system. The studied variable is to change the volumetric flow rate of air from (750 cfm) to (2000 cfm) of the dry side, and from (750 cfm) to (2500 cfm) of the wet side. The pipe length was changed from (20 cm) to (45 cm), and its diameter from (0.5 cm) to (3 cm). Those were the design changes. On the environmental changes, we studied the effect of changing the temperature on the dry or wet bulb of the system. The study is taken place in Tikrit University (34. 35N; 43.37 E), to determine the suitability of the weather conditions of the region for the work of the system. It was taken place in the late August for two consecutive days, with readings of 24 hours. The results show that the best quantity of the air supplied, which represent the best performance of the system (750 cfm) and (1000 cfm) for the wet side when the diameter (1-1.5 cm) and length is (45 cm). The results show also the possibility of the work of this system for the region mentioned because it is characterized by its hot and dry climate in the summer, as the efficiency of evaporative evaporator increases the hot and dry environment by 80%.

Publisher

Tikrit University

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3