Affiliation:
1. Department of Environmental Engineering and Health, Chia Nan University of Pharmacy and Science, Tainan,Taiwan 717
Abstract
The specific filtration resistance, moisture, and SVI were used to evaluate the influence of pH on the filtration and dewatering efficiencies when applying Fenton's reagent to treat the excess sludge. The excess sludge used in this study was obtained from the wastewater treatment plant of An-Ping Industrial Park in Tainan, Taiwan. Results show that initial pH has no significant effect on the filtration efficiency of sludge by using the Fenton (Fe2+/H2O2) system as the treatment process. However, the reduction of specific resistance by Fenton-like (Fe3+/H2O2) process decreased suddenly to a level similar to that obtained from the control experiment at initial pH > 4.5. For the moisture of cake sludge, both Fenton and Fenton-like systems have the same tendency; the moisture of cake sludge increased slightly with increasing the initial pH. The SVI values for Fenton process decreased with increasing the initial pH, but the opposite result was obtained from the Fenton-like and control system; higher pH was not favorable for the sludge settling.
Subject
Water Science and Technology,Environmental Engineering
Cited by
72 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献