Development of free 25-hydroxyvitamin D3 assay method using liquid chromatography-tandem mass spectrometry

Author:

Ishimine Nau1,Wu Shixing1,Ota Ryusei2,Takahashi Koji3,Takiwaki Masaki3,Sugano Mitsutoshi4,Tozuka Minoru5,Uehara Takeshi16ORCID

Affiliation:

1. 1Department of Laboratory Medicine, Shinshu University Hospital, Matsumoto, Japan

2. 2Division of Medical Technology, School of Health Sciences, Shinshu University School of Medicine, Matsumoto, Japan

3. 3Medical Equipment Business Operations, JEOL Ltd., Tokyo, Japan

4. 4Department of Clinical Laboratory Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Japan

5. 5Life Science Research Center, Nagano Children’s Hospital, Azumino, Japan

6. 6Department of Laboratory Medicine, Shinshu University School of Medicine, Matsumoto, Japan

Abstract

Abstract The free hormone hypothesis has triggered controversies regarding the measurement of free vitamin D metabolites, such as free 25-hydroxyvitamin D (25(OH)D), as a suitable indicator for total vitamin D for clinical use. This issue can be addressed by developing a precise and accurate method for free 25(OH)D measurement. In the present study, a novel assay method for free 25(OH)D3 based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. Sample preparation first involved ultrafiltration to remove vitamin D-binding protein-bound and albumin-bound 25(OH)D, followed by extraction with a column, derivatization, evaporation, dissolution, and injection into the LC-MS/MS system. The coefficient of variation of repeatability and reproducibility obtained were 3.8–4.5% and 4.8–5.9%, respectively. Satisfactory linearity (r=0.999) was obtained up to 80 pg/ml. The lower quantification limit was 0.97 pg/ml and the S/N ratio on the peak of 1.0 pg/ml sample was 24.8 (which is more than the acceptable value of 10). The recovery rate was between 84.5 and 92.4% with a negligible matrix effect (94.5–104.9%). Levels of free 25(OH)D3, but not total 25(OH)D3, in the serum of the patients with chronic kidney disease (CKD) and hepatic cirrhosis (HC) were substantially lower than those in healthy subjects. The correlation coefficient between total and free 25(OH)D3 was 0.738 in all samples, while the linear regression equations were different between the patients with CKD and HC. In conclusion, LC-MS/MS assay for free 25(OH)D3 might be useful to evaluate high-throughput methods, including ELISA.

Publisher

Portland Press Ltd.

Subject

Cell Biology,Molecular Biology,Biochemistry,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3