Abstract

ImportanceCochlear implantation produces remarkable results in postlingual deafness, although auditory outcomes vary. Electrocochleography (ECochG) has emerged as a valuable tool for assessing the cochlear-neural substrate and evaluating patient prognosis.ObjectiveTo assess whether ECochG-total response (ECochG-TR) recorded at the best-frequency electrode (BF-ECochG-TR) correlates more strongly with speech perception performance than ECochG-TR measured at the round window (RW-ECochG-TR).Design, Setting, and ParticipantsThis single-center cross-sectional study recruited 142 patients from July 1, 2021, to April 30, 2022, with 1-year follow-up. Exclusions included perilymph suctioning, crimped sound delivery tubes, non–native English speakers, inner ear malformations, nonpatent external auditory canals, or cochlear implantation revision surgery.ExposuresCochlear implantation.Main Outcomes and MeasuresSpeech perception testing, including the consonant-nucleus-consonant (CNC) words test, AzBio sentences in quiet, and AzBio sentences in noise plus 10-dB signal to noise ratio (with low scores indicating poor performance and high scores indicating excellent performance on all tests), at 6 months postoperatively; and RW-ECochG-TR and BF-ECochG-TR (measured for 250, 500, 1000, and 2000 Hz).ResultsA total of 109 of the 142 eligible postlingual adults (mean [SD] age, 68.7 [15.8] years; 67 [61.5%] male) were included in the study. Both BF-ECochG-TR and RW-ECochG-TR were correlated with 6-month CNC scores (BF-ECochG-TR: r = 0.74; 95% CI, 0.62-0.82; RW-ECochG-TR: r = 0.67; 95% CI, 0.54-0.76). A multivariate model incorporating age, duration of hearing loss, and angular insertion depth did not outperform BF-ECochG-TR or RW-ECochG-TR alone. The BF-ECochG-TR correlation with CNC scores was significantly stronger than the RW-ECochG-TR correlation (r difference = −0.18; 95% CI, −0.31 to −0.01; z = −2.02). More moderate correlations existed between 6-month AzBio scores in noise, Montreal Cognitive Assessment (MoCA) scores (r = 0.46; 95% CI, 0.29-0.60), and BF-ECochG-TR (r = 0.42; 95% CI, 0.22-0.58). MoCA and the interaction between BF-ECochG-TR and MoCA accounted for a substantial proportion of variability in AzBio scores in noise at 6 months (R2 = 0.50; 95% CI, 0.36-0.61).Conclusions and RelevanceIn this case series, BF-ECochG-TR was identified as having a stronger correlation with cochlear implantation performance than RW-ECochG-TR, although both measures highlight the critical role of the cochlear-neural substrate on outcomes. Demographic, audiologic, and surgical factors demonstrated weak correlations with cochlear implantation performance, and performance in noise was found to require a robust cochlear-neural substrate (BF-ECochG-TR) as well as sufficient cognitive capacity (MoCA). Future cochlear implantation studies should consider these variables when assessing performance and related interventions.

Publisher

American Medical Association (AMA)

Subject

Otorhinolaryngology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3