Linear Accuracy of Cone Beam CT Derived 3D Images

Author:

Brown April A.1,Scarfe William C.2,Scheetz James P.3,Silveira Anibal M.4,Farman Allan G.2

Affiliation:

1. a MS in Oral Biology candidate, Graduate School, University of Louisville School of Dentistry, Louisville, Ky

2. b Professor, Department of Surgical/Hospital Dentistry, University of Louisville School of Dentistry, Louisville, Ky

3. c Professor, Department of Diagnostic Sciences, Prosthetic and Restorative Dentistry, University of Louisville School of Dentistry, Louisville, Ky

4. d Professor, Department of Orthodontic and Pediatric Dentistry, University of Louisville School of Dentistry, Louisville, Ky

Abstract

Abstract Objective: To compare the in vitro reliability and accuracy of linear measurements between cephalometric landmarks on cone beam computed tomography (CBCT) 3D volumetric images with varying basis projection images to direct measurements on human skulls. Materials and Methods: Sixteen linear dimensions between 24 anatomic sites marked on 19 human skulls were directly measured. The skulls were imaged with CBCT (i-CAT, Imaging Sciences International, Hatfield, Pa) at three settings: (a) 153 projections, (b) 306 projections, and (c) 612 projections. The mean absolute error and modality mean (± SD) of linear measurements between landmarks on volumetric renderings were compared to the anatomic truth using repeated measures general linear model (P ≤ .05). Results: No difference in mean absolute error between the scan settings was found for almost all measurements. The average skull absolute error between marked reference points was less than the distances between unmarked reference sites. CBCT resulted in lower measurements for nine dimensions (mean difference range: 3.1 mm ± 0.12 mm to 0.56 mm ± 0.07 mm) and a greater measurement for one dimension (mean difference 3.3 mm ± 0.12 mm). No differences were detected between CBCT scan sequences. Conclusions: CBCT measurements were consistent between scan sequences and for direct measurements between marked reference points. Reducing the number of projections for 3D reconstruction did not lead to reduced dimensional accuracy and potentially provides reduced patient radiation exposure. Because the fiducial landmarks on the skulls were not radio-opaque, the inaccuracies found in measurement could be due to the methods applied rather than to innate inaccuracies in the CBCT scan reconstructions or 3D software employed.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3