Left Atrial Appendage Analysis from Echocardiographic Images: Relevance in Left Atrial Appendage Occlusion

Author:

Samareh Hemmati Sarapardeh Haniyeh1,Fayazi Ali2ORCID,Ghayoumi Zadeh Hossein1,Rezaee Khosro3

Affiliation:

1. Department of Electrical Engineering, Vali-e-Asr University of Rafsanjan 1 , 22 Bahman Square, Rafsanjan7718897111, Iran , https://orcid.org/0000-0002-5390-3938 (H.G.Z.)

2. Department of Electrical Engineering, Vali-e-Asr University of Rafsanjan 2 , 22 Bahman Square, Rafsanjan7718897111, Iran (Corresponding author), e-mail: a.fayazi@vru.ac.ir , ORCID link for author moved to before name tags https://orcid.org/0000-0003-3237-1060

3. Department of Biomedical Engineering, Meybod University 3 , Meybod8961699557, Iran

Abstract

Abstract Atrial fibrillation, a prevalent cardiac arrhythmia, disrupts the normal path of electrical signals within the heart. To address this issue, the left atrial appendage closure is often considered. This involves using a closure instrument named the Watchman to obstruct the left atrial appendage (LAA) ostium. The wide variety of LAA shapes, sizes, and forms in individuals makes selecting the correct Watchman size crucial. This study first isolates the LAA from echocardiographic images and then recommends the appropriate Watchman size. The 3-D echocardiographic images used in this study are from 32 male and female patients who underwent successful LAA closure at Kings College Hospital London over two years. For each patient, there are 208 cardiac echo slices in the imaging mode. This study presents an image processing-based model to separate LAA regions and extract relevant features. These features are then inputted into a classification platform in which a neural network determines the suitable Watchman size. The average and mode Hausdorff distances, calculated between the proposed method and the traditional manual calculation for the 501 analyzed LAA images, are approximately 0.2467 and 0.0587, respectively. Because of limited data, a 10-fold cross-validation was used to assess the classifier, yielding an accuracy of 74.07 %. The proposed model effectively isolated the LAA from the corresponding slices of the 3-D echocardiographic images. However, the classifier’s accuracy is not ideal because of insufficient data, which could be improved by expanding the database. This research’s outcomes could aid physicians in selecting the proper Watchman size.

Publisher

ASTM International

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3