Calculation of the estimated glomerular filtration rate using the 2021 CKD-EPI creatinine equation and whole blood creatinine values measured with Radiometer ABL 827 FLEX
Author:
Song Lu1, Buggs Vincent1, Samara Vishnu Amaram1, Bahri Shadfar2
Affiliation:
1. Department of Pathology and Laboratory Medicine , David Geffen School of Medicine, University of California Los Angeles , Los Angeles , CA , USA 2. Department of Molecular and Medical Pharmacology , Division of Nuclear Medicine, David Geffen School of Medicine, University of California Los Angeles , Los Angeles , CA , USA
Abstract
Abstract
Objectives
Estimated glomerular filtration rate (eGFR) can be calculated using serum/plasma creatinine measured with automated chemistry analyzers. It is unclear whether eGFR can be calculated using creatinine values measured in whole blood (WB creatinine). The aim of this study is to determine the comparability between the eGFR calculated using WB creatinine and plasma creatinine.
Methods
Blood samples from 1,073 patients presented to the emergency department (ED), perioperative areas, intensive care unit (ICU) or nuclear medicine were used to determine the accuracy of WB creatinine. For each sample, WB creatinine was first measured with Radiometer ABL827 FLEX blood gas analyzer, then plasma creatinine was measured with Roche Cobas702 chemistry analyzer after samples were centrifuged. In a subset of 247 samples with the information of age and sex, whole blood eGFR (WB eGFR) and plasma eGFR were calculated using WB creatinine and plasma creatinine and the 2021 chronic kidney disease epidemiology collaboration (CKD-EPI) creatinine equation, respectively.
Results
WB creatinine correlated with plasma creatinine linearly with a slope of 1.06 and an intercept of −0.01. The coefficient of determination (R2) was 0.99. WB eGFR correlated with plasma eGFR linearly with a slope of 0.95, intercept of −1.63, and R2 of 0.97. Comparing to plasma eGFR, the sensitivity and specificity for WB eGFR to identify those with high risk (eGFR<30 mL/min/1.73 m2) and low risk (eGFR>45 mL/min/1.73 m2) for kidney injuries was 100 and 92.2%, respectively. The overall concordance in classifying the four stages of kidney damage between WB eGFR and plasma eGFR was 87.9%.
Conclusions
WB creatinine measured with Radiometer ABL827 Flex can be used to calculate eGFR using the 2021 CKD-EPI creatinine equation. The sensitivity and specificity for WB eGFR to identify those with high and low risks for potential kidney injuries are acceptable in patients needing rapid assessment of their kidney functions.
Publisher
Walter de Gruyter GmbH
Subject
Biochemistry (medical),Clinical Biochemistry,General Medicine
Reference18 articles.
1. Yi, X, Leung, EKY, Mika, D, Wolsky, RJ, Slambrouck, CV, Leanse, J, et al.. Reengineering critical laboratory testing for timely chemotherapeutic management. J Appl Lab Med. 2018;3:240–9. https://doi.org/10.1373/jalm.2017.025973. 2. Morita, S, Suzuki, K, Masukawa, A, Ueno, E. Assessing renal function with a rapid, handy, point-of-care whole blood creatinine meter before using contrast materials. Jpn J Radiol. 2011;29:187–93. https://doi.org/10.1007/s11604-010-0536-8. 3. Levey, AS, Stevens, LA, Schmid, CH, Zhang, YL, Castro, AF, Feldman, HI, et al.. A new equation to estimate glomerular filtration rate. Ann Intern Med. 2009;150:604–12. 4. Chu, CD, McCulloch, CE, Banerjee, T, Pavkov, ME, Burrows, NR, Gillespie, BW, et al.. CKD awareness among US adults by future risk of kidney failure. Am J Kidney Dis. 2020;76:174–83. 5. Delgado, C, Baweja, M, Crews, DC, Eneanya, ND, Gadegbeku, CA, Inker, LA, et al.. A unifying approach for GFR estimation: recommendations of the NKF-ASN task force on reassessing the inclusion of race in diagnosing kidney disease. Am J Kidney Dis 2022;79:68–288. https://doi.org/10.1053/j.ajkd.2021.08.003.