Total bilirubin assay differences may cause inconsistent treatment decisions in neonatal hyperbilirubinaemia

Author:

Thomas David H.1,Warner Janet V.2,Jones Graham R.D.3,Chung Jason Z.Y.4ORCID,Macey David J.5,Screnci Antonella6,Ryan Joshua B.7

Affiliation:

1. Clinical Chemistry Liverpool Hospital, NSW Health Pathology , NSW Health Pathology, Liverpool , NSW , Australia

2. Faculty of Medicine , The University of QLD , Saint Lucia , QLD , Australia

3. SydPath, St Vincent’s Hospital, Sydney , Darlinghurst , Australia

4. Department of Biochemistry , Children’s Hospital at Westmead , Westmead , NSW , Australia

5. Central Automated Laboratory and Biochemistry, Douglass Hanly Moir Pathology , Macquarie Park , NSW , Australia

6. Department of Chemical Pathology , St Vincent’s Pathology , Darlinghurst , NSW , Australia

7. Department of Chemical Pathology , Institute of Clinical Pathology and Medical Research, Westmead Hospital , Westmead , NSW , Australia

Abstract

Abstract Objectives To assess interlaboratory variability of total serum bilirubin (TSB) results in newborns. Initiated following a clinical incident in which a neonate was transferred to a tertiary hospital for treatment of severe hyperbilirubinemia but on arrival was reclassified into a lower risk category due to a 20% difference in TSB between laboratories. Methods Fresh residual plasma samples from hospital-born infants were pooled to obtain 11 samples across a range of total bilirubin concentrations. Aliquots were light-protected and measured on 7 commercial platforms at 4 accredited medical laboratories. Data from The Royal College of Pathologists of Australasia Quality Assurance Programs’ (RCPAQAP) Neonatal Bilirubin program was analysed. Results Twenty-four to 30% difference in results for individual samples, largely due to calibration differences between assays. When interpreted according to guidelines, results from different platforms would have led to different clinical interventions in some cases. RCPAQAP results showed significant within-method bias but were not shown to be commutable with patient samples. Conclusions There are clinically significant method-dependent differences in TSB results from neonatal samples, consistent with our clinical incident. The differences are largely due to lack of standardisation of calibrator values. This has implications for healthcare resource use and possibly for the neurodevelopment of infants. Intervention is needed at a number of levels, including clinical reporting of incidents arising from discordant results, commitment by manufacturers to ensure metrological traceability of methods with sufficiently low uncertainty in the final measurements, and availability of commutable quality assurance material to monitor assay performance, especially at the clinical decision points for neonatal jaundice.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3