Reliability analysis of the heart autonomic control parameters during hemodialysis sessions

Author:

da Silva Débora Martins,Macedo Murilo Carneiro,Lemos Lucas Brasileiro,Vieira Fernando Costa,Pirôpo Uanderson Silva,Andrade Helder Brito,Wessel Niels,Pereira Rafael

Abstract

AbstractThe study of heart autonomic control (HAC) in patients with chronic kidney disease (CKD) undergoing dialysis treatment has been carried out, however, there are no studies reporting the reliability of measurements of HAC parameters involving the mentioned samples and conditions. The reliability of many HAC parameters was evaluated from patients with CKD during two sessions of hemodialysis. The successive R-R intervals were recorded during two sessions of hemodialysis from 14 CKD patients that were undergoing dialysis for at least 6 months and with no history of recurrent hypotensive events. HAC parameters were obtained with time and frequency domain analysis, as well as with nonlinear methods. The reliability was measured with the intraclass correlation coefficient (ICC). The results showed excellent reliability (ICC=0.90–0.98) for most heart rate variability (HRV) parameters, especially the parameters obtained in the time domain [square root of the mean squared differences between successive R-R intervals (RMSSD), percentage of adjacent R-R intervals that differ by more than 50 ms (pNN50), mean of the 5-min standard deviations of R-R intervals (SDNNi), and triangular index] and with non-linear methods [standard deviation of the instantaneous variability beat-to-beat (SD1), standard deviation in long-term continuous R-R intervals (SD2), detrended fluctuation analysis (DFA) α1 and α2, approximate and sample entropies, and correlation dimension (D2): ICC=0.86–0.96]. Among the parameters obtained in the frequency domain (normalized magnitude from the spectrum of low-frequency components (LFnu), normalized magnitude from the spectrum of high-frequency components (HFnu), and LF/HF ratio), the LF/HF ratio showed better reliability (ICC=0.96 vs. ICC=0.70). Measurements of HAC parameters have excellent test-retest reliability for the studied samples and conditions.

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3