Method development for quantitative determination of seven statins including four active metabolites by means of high-resolution tandem mass spectrometry applicable for adherence testing and therapeutic drug monitoring

Author:

Wagmann Lea1,Hemmer Selina12,Caspar Achim T.1,Meyer Markus R.1

Affiliation:

1. Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Center for Molecular Signaling (PZMS), Saarland University, Homburg, Germany

2. Department of Food Chemistry and Toxicology, Technical University Kaiserslautern, Kaiserslautern, Germany

Abstract

AbstractBackgroundStatins are used to treat and prevent cardiovascular diseases (CVDs) by reducing the total serum cholesterol concentration. Unfortunately, dose-related side effects and sub-optimal response, attributed to non-adherence amongst others, were described. Therefore, a fast and sensitive liquid chromatography-high-resolution tandem mass spectrometry (LC-HRMS/MS) method for adherence testing and therapeutic drug monitoring of all currently marketed statins and their active metabolites in human blood plasma should be developed, validated and tested for applicability.MethodsAtorvastatin, fluvastatin, lovastatin, pitavastatin, pravastatin, rosuvastatin, and simvastatin, as well as ortho- and para-hydroxy-atorvastatin, lovastatin hydroxy acid and simvastatin hydroxy acid were included and several internal standards (IS) tested. Validation was performed according to the guideline of the European Medicines Agency including selectivity, carry-over, accuracy, precision, matrix effects, dilution integrity and analyte stability. Finally, applicability was tested using 14 patient samples submitted for regular toxicological analysis.ResultsDue to an analytical interference of atorvastatin-d5, diazepam-d5 and pentobarbital-d5 were chosen as IS for positive and negative ionization mode, respectively. All statins and metabolites fulfilled the validation acceptance criteria except for fluvastatin, which could not be quantified reliably and reproducibly, most probably due to instability. Analyses of human plasma samples revealed concentrations of statins and metabolites below the reference plasma concentrations in the case of eight patients. However, nothing was known concerning patients’ adherence and time between intake and sampling.ConclusionsAn LC-HRMS/MS method for identification and quantification of atorvastatin, lovastatin, pitavastatin, pravastatin, rosuvastatin, simvastatin and four active metabolites was successfully developed and applicability demonstrated.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3