Mechanical testing and engineering applicability analysis of SAP concrete used in buffer layer design for tunnels in active fault zones
Author:
Jun Cao12, Zheshu Wu3, Zhen Cui12, Xiancheng Mei12
Affiliation:
1. State Key Laboratory of Geomechanics and Geotechnical Engineering, Institute of Rock and Soil Mechanics, Chinese Academy of Sciences , Wuhan , Hubei 430071 , China 2. School of Engineering Science, University of Chinese Academy of Sciences , Beijing , 10049 , China 3. China Railway Siyuan Survey and Design Group Co., Ltd. , Wuhan , Hubei, 430063 , China
Abstract
Abstract
To tackle the challenge of dislocation damage when tunnels traverse active fault zones, this study introduces the concept of using brittle buffer materials for anti-dislocation. Building on this concept, we propose a novel concrete buffer material utilizing large-sized spherical super absorbent polymers (SAP) as a porogen, aimed at ensuring the safety of tunnel structures during active fault dislocations. To investigate the feasibility and superiority of SAP concrete as a buffer material compared to other similar materials, we prepared samples with three different SAP concrete proportions and conducted a series of physical and mechanical tests. The results show that SAP pre-hydrated with 0.2 mol·L−1 sodium carbonate solution exhibits a slower rate of moisture loss in the cement slurry, aiding the hydration reaction of concrete. The permeability coefficient of SAP concrete is approximately 10−7 cm·s−1, slightly lower than foam concrete of the same density level. SAP concrete buffer material demonstrates significant brittleness, in contrast to the mostly ductile nature of other buffers such as foam concrete and rubberized concrete. Utilizing the brittle nature of SAP concrete materials, when applied to tunnels affected by stick–slip active fault dislocations, its instantaneous loss of compressive capacity provides excellent yield performance, thus protecting the tunnel lining from damage. However, under certain circumferential pressure conditions, both the peak and residual strength of SAP concrete significantly increase. High peak and residual strengths do not favor the effective buffering effect of SAP concrete; therefore, an approach involving the intermittent arrangement of precast buffer blocks has been proposed for application.
Publisher
Walter de Gruyter GmbH
Reference38 articles.
1. Uenishi, K. and S. Sakurai. Characteristic of the vertical seismic waves associated with the 1995 Hyogo-ken Nanbu (Kobe), Japan earthquake estimated from the failure of the Daikai underground station. Earthquake Engineering & Structural Dynamics, Vol. 29, No. 6, 2000, pp. 813–821. 2. Bray, J. D. Developing mitigation measures for the hazards associated with earthquake surface fault rupture. In Proc. workshop on seismic fault-induced failures—possible remedies for damage to urban facilities, University of Tokyo, Japan, 2001, 55–79. 3. Gundes Bakir, P., G. De Roeck, G. Degrande, and K. K. F. Wong. Site dependent response spectra and analysis of the characteristics of the strong ground motion due to the 1999 Duzce earthquake in Turkey. Engineering Structures, Vol. 29, No. 8, 2007, pp. 1939–1956. 4. O’Rourke, T. D., S. H. Goh, C. O. Menkiti, and R. J. Mair. Highway tunnel performance during the 1999 Duzce earthquake. In Proceedings of the Fifteenth International Conference on Soil Mechanics and Geotechnical Engineering; 27-31 August 2001, 2, Istanbul, 1365–1368. 5. Yang, H. W. and J. Beeson. The setback distance concept and 1999 Chi-Chi (Taiwan) earthquake. In Proceedings of the Fourth International Conference on Recent Advances in Geotechnical Earthquake Engineering and Soil Dynamics. CD-ROM, paper no. 10.56, Prakash, S., eds, University of Missouri-Rolla, San Diego, 2001.
|
|