Determination of benzene, toluene, ethylbenzene and xylene in field and laboratory by means of cold fiber SPME equipped with thermoelectric cooler and GC/FID method

Author:

Tajik Leila1,Bahrami Abdulrahman1,Ghiasvand Alireza2,Shahna Farshid Ghorbani1

Affiliation:

1. Hamadan University of Medical Sciences , Center of Excellence for Occupational Health, School of Public Health , Hamadan , Iran (Islamic Republic of)

2. Lorestan University , Department of Chemistry, Faculty of Science , Khoramabad , Iran (Islamic Republic of)

Abstract

Abstract A simple and effective cooling device based on a thermoelectric cooler was applied to cool the SPME fiber. The device was used for quantitative extraction of aromatic hydrocarbons in the air. Several factors such as coating temperature, extraction temperature and relative humidity in the laboratory setting were optimized. Comparison of the results between the cold fiber SPME (CF-SPME) and NIOSH 1501 method on standard test atmosphere indicated a satisfactory agreement. The CF-SPME and SPME method were also compared. The results revealed that CF-SPME has the most appropriate outcome for the extraction of aromatic hydrocarbons from the ambient air. The cold fiber SPME technique showed good results for several validation parameters. Under the optimized conditions, the limits of detection (LOD) and the limits of quantification (LOQ) ranged from 0.00019 to 0.00033 and 0.0006 to 0.001 ng ml−1, respectively. The intra-day relative standard deviation (RSD) showed ranging from 4.8 to 10.5%.

Publisher

Walter de Gruyter GmbH

Subject

General Chemical Engineering,General Chemistry,Biotechnology

Reference36 articles.

1. 1. Hazrati, S., Rostami, R., Fazlzadeh, M. & Pourfarzi, F. (2016). Benzene, toluene, ethylbenzene and xylene concentrations in atmospheric ambient air of gasoline and CNG refueling stations. Air Qual Atmos Health. 9, 403–409. DOI: 10.1007/s11869-015-0349-0.10.1007/s11869-015-0349-0

2. 2. Elke, K., Jermann, E., Begerow, J. & Dunemann, L. (1998). Determination of benzene, toluene, ethylbenzene and xylenes in indoor air at environmental levels using diffusive samplers in combination with headspace solid-phase microextraction and highresolution gas chromatography–flame ionization detection. J. Chromatogr. A. 826, 191–200. DOI: 10.1016/S0021-9673(98)00736-5.10.1016/S0021-9673(98)00736-5

3. 3. Tumbiolo, S., Gal, J.F., Maria, P.C. & Zerbinati, O. (2005). SPME sampling of btex before gc/ms analysis: examples of outdoor and indoor air quality measurements in public and private sites. Ann. Chim. 95, 757–766. DOI: 10.1002/adic.200590089.10.1002/adic.200590089

4. 4. Lee, M.R., Chang, C.M. & Dou, J. (2007). Determination of benzene, toluene, ethylbenzene, xylenes in water at sub-ng l-1 levels by solid-phase microextraction coupled to cryo-trap gas chromatography-mass spectrometry. Chemosphere 69, 1381–1387. DOI: 10.1016/j.chemosphere.2007.05.004.10.1016/j.chemosphere.2007.05.004

5. 5. Hoskins, J.A. (2011). Health effects due to indoor air pollution. Survival and sustainability. (pp. 665–676). Springer, Berlin Heidelberg.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3