Realization of a multi-layer EIT-system

Author:

Busch Christoph1,Schullcke Benjamin1,Moeller Knut1

Affiliation:

1. Furtwangen University, Institute of Technical Medicine, Germany

Abstract

AbstractElectrical Impedance Tomography (EIT) is an imaging technique used for monitoring of ventilation distribution in the lung. Small alternating currents are injected and resulting voltages are measured on the body surface with electrodes fixed around the thorax. Two-dimensional EIT (2D-EIT) is the most common technique in clinical applications but enables visualization of only one horizontal slice of the thorax. However, additional information in the cranio-caudal direction is necessary to more comprehensively assess the ventilation distribution.3D-EIT systems address this issue, but clinically approved systems are not yet available. The aim of this study is to realize a multi-layer EIT-system with several electrode planes. An approved EIT system functions as basis for this development (PulmoVista 500, Dräger, Lübeck, Germany). Two planes were used for the technical realization of the multi-layer EIT-system. The alternation between the planes was realised using analog switches, which were controlled via a frequency generator and transfer the injected current and the measured voltages between the different electrode planes and the EIT device. The multi-layer EIT-System was applied to a phantom tank for first pilot measurements.Results on the phantom tank with non-conductive targets at different heights reveal that the system is capable of providing information in the cranio-caudal direction. The high frame rates of EIT images combined with the high switching speed of the used analog switches enable real-time acquisition of ventilation at different thoracic planes. Thus, the modified EIT device makes it possible to comprehensively monitor the redistribution of air in the lungs during a breathing cycle, not only in a single plane, but also in the cranio-caudal direction.

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. 3D Image Reconstruction based on Electrical Impedance Tomography Measurements using a Gauss-Newton Algorithm;2021 International Workshop on Impedance Spectroscopy (IWIS);2021-09-29

2. Towards a thoracic conductive phantom for EIT;Medical Engineering & Physics;2020-03

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370