Abstract

Aims: To compare the changes of central corneal thickness (CCT) and intraocular pressure (IOP) post-phacoemulsification between cataract patients with and without pre-existing glaucoma. Materials and methods: A prospective cohort study of 86 patients with visually significant cataract: 43 with pre-existing glaucoma (GC group) and 43 without pre-existing glaucoma (CO group). CCT and IOP were evaluated at baseline (pre-phacoemulsification), as well as at 2 hours, 1 day, 1 week and 6 weeks post-phacoemulsification. Results: The GC group have significantly thinner CCT pre-operatively (p = 0.003). There was a steady increase of CCT with the highest peak at 1 day post-phacoemulsification, followed by a steady decline of CCT and back to baseline at 6 weeks post-phacoemulsification in both groups. The GC group demonstrated a significant difference in CCT at 2 hours (mean difference 60.2 μm, p = 0.003) and 1 day (mean difference 70.6 μm, p = 0.002) post-phacoemulsification, compared to the CO group. There was a sudden increase in IOP at 2 hours post-phacoemulsification measured by GAT and DCT in both groups. This was followed by a gradual reduction of IOP, with significant reduction at 6 weeks post-phacoemulsification in both groups. However, there was no significant difference in IOP between the two groups. IOP measured by GAT and DCT showed strong correlation (r > 0.75, p < 0.001) in both groups. There was no significant correlation between GAT-IOP and CCT changes; nor between DCT-IOP and CCT changes in both groups. Conclusions: CCT changes post-phacoemulsification in patients with pre-existing glaucoma were similar, in spite of having thinner CCT pre-operatively. IOP measurement was not affected by CCT changes in glaucoma patients post-phacoemulsification. IOP measurement using GAT is comparable with DCT post-phacoemulsification.

Publisher

Czech Society of Ophthalmology of the CzMA

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3