Are aligners capable of inducing palatal bodily translation or palatal root torque of upper central incisors? A biomechanical in vitro study

Author:

Elkholy Fayez,Weber Sophia,Repky Stefan,Jäger Rudolf,Schmidt Falko,Lapatki Bernd G.

Abstract

Abstract Objectives Previous studies have shown that aligners have limited ability to control root movements. The purpose of this study was to investigate which modification geometry and foil thickness are optimal for generating the force-moment (F/M) systems required for palatal root torque of maxillary central incisors. Materials and methods Tooth 11 was separated from a maxillary acrylic model and connected to a movement unit via a 3D F/M sensor. Different modification geometries (crescent, capsular, double-spherical) with different depths were digitally implemented in the labio-cervical region of tooth 11 to induce an increased contact force. We evaluated the F/M systems exerted by aligners with thicknesses of 0.4–1.0 mm. F/M measurements were taken with tooth 11 in the neutral position and during palatal displacement of tooth 11 (simulating its initial clinical movement). Results The mechanical requirements of palatal root torque are a palatally directed force (− Fy) and a palatal root torquing moment (− Mx). These requirements were reliably achieved with modification depths > 0.5 mm. The modification depth and foil thickness had a significant influence on − Fy magnitudes (linear mixed-effect models, p < 0.01). With the 0.75-mm aligners combined with 1.5-mm deep modifications, the palatal root torque range (palTR) started after an initial palatal crown displacement of 0.09, 0.12, and 0.12 mm for the capsular, crescent, and double-spherical modification geometries, respectively. Conclusions A relatively early start of the palatal torque range (after a 0.1-mm palatal crown displacement) and appropriate − Fy magnitudes were achieved with 0.75-mm-thick aligners containing 1.5-mm deep capsular or crescent pressure regions. Subsequent clinical trials are required to confirm the clinical effects of these modifications. Clinical relevance In vitro testing indicated that modified aligners are capable of generating the F/M components required for palatal root torque of upper central incisors.

Funder

Universitätsklinikum Ulm

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3