Influence of flow rate and different size of suction cannulas on splatter contamination in dentistry: results of an exploratory study with a high-volume evacuation system

Author:

Graetz ChristianORCID,Hülsbeck Viktor,Düffert Paulina,Schorr Susanne,Straßburger Martin,Geiken Antje,Dörfer Christof E.,Cyris Miriam

Abstract

Abstract Objectives SOPs recommend high-volume evacuation (HVE) for aerosol-generating procedures (AGPs) in dentistry. Therefore, in the exploratory study, the area of splatter contamination (SCON in %) generated by high-speed tooth preparation (HSP) and air-polishing (APD) was measured when different suction cannulas of 6 mm diameter (saliva ejector (SAE)), 11 mm (HC11), or 16 mm (HC16) were utilized versus no-suction (NS). Materials and methods Eighty tests were performed in a closed darkened room to measure SCON (1m circular around the manikin head (3.14 m2) via plan metrically assessment through fluorescence technique. HSP (handpiece, turbine (Kavo, Germany)) or APD (LM-ProPowerTM (Finland), Airflow®-Prophylaxis-Master (Switzerland)) for 6 min plus 5 s post-treatment were performed either without suction or with low-flow (150 l/min for SAE) or high-flow rate (250 l/min/350 l/min for HC11/HC16) suction. All tests were two-tailed (p≤0.05, Bonferroni corrected for multi-testing). Results Irrespective the AGP, SCON was higher for NS (median [25th; 75th percentiles]: 3.4% [2.6; 5.4]) versus high-flow suction (1.9% [1.5; 2.5]) (p=0.002). Low-flow suction (3.5% [2.6; 4.3]) versus NS resulted in slightly lower but not statistically significantly lower SCON (p=1.000) and was less effective than high-flow suction (p=0.003). Lowest contamination values were found with HC16 (1.9% [1.5; 2.5]; p≤0.002), whereat no significant differences were found for HC11 (2.4% [1.7; 3.1]) compared to SAE (p=0.385) or NS (p=0.316). Conclusions Within study’s limitations, the lowest splatter contamination values resulted when HC16 were utilized by a high-flow rate of ≥250 l/min. Clinical relevance It is strongly recommended to utilize an HVE with suction cannulas of 16mm diameter for a high-flow rate during all AGPs and afterwards also to disinfect all surface of patients or operators contacted.

Funder

Universitätsklinikum Schleswig-Holstein - Campus Kiel

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3