Abstract
Abstract
Introduction
Palmar plate fixation of the distal radius fracture involves dissecting the pronator quadratus (PQ). This is regardless of whether the approach is radial or ulnar to the flexor carpi radialis (FCR) tendon. It is not yet clear whether and to what extent this dissection leads to a functional loss of pronation or pronation strength. The aim of this study was to investigate the functional recovery of pronation and pronation strength after dissection of the PQ without suturing.
Materials and methods
From October 2010 to November 2011, patients aged over 65 with fracture were prospectively enrolled in this study. Fracture stabilisation was performed via the FCR approach without suturing the PQ. Follow-up examinations took place 8 weeks and 12 months postoperatively, and pronation and supination strength were analysed by means of an especially developed measuring device.
Results
212 patients were initially screened and 107 were enrolled. The range of motion compared to the healthy opposite side was Ext/Flex 75/66% 8 weeks postoperatively. Pronation was 97% with a pronation strength of 59%. After 1 year, the scores improved to Ext/Flex 83/80%. Pronation recovered to 99% and pronation strength to 78%.
Conclusion
The present study can show a recovery of pronation as well as pronation strength in a large patient population. At the same time, the pronation strength is still significantly lower 1 year after the operation than on the opposing healthy side. As the pronation strength recovers as the grip strength and is at all times on a par with the supination strength, we believe that we can continue to refrain from re-fixating the pronator quadratus.
Funder
Universitätsmedizin Rostock
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,General Medicine,Surgery,Surgery
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献