Abstract
Abstract
Purpose
The Vibrant Soundbridge (VSB) is an established active-middle-ear-implant for patients with moderate-to-profound hearing-loss. This surgery is referred to as “Vibroplasty”. Sufficient transfer of the VSB’s floating-mass-transducers (FMT) energy to the inner ear is a crucial factor influencing the coupling-quality (CQ). However, assessing CQ is hamper by two issues: the method of CQ-assessment itself and the method of FMT-fixation during Vibroplasty.
Methods
This prospective study explored the influence of intraoperative auditory-brainstem-response (+ ABR) measurements and various fixation methods on postoperative CQ after Vibroplasty as compared to matched-patients after Vibroplasty without intraoperative ABR (-ABR). Propensity-score-matching was performed based on preoperative bone-conduction-pure-tone-average-3 (BC-PTA3) at 1-, 2- and 4 kHz. Primary outcome parameters were postoperative CQ-PTA3, intraoperative ABR threshold for various fixation methods and postoperative BC-PTA3.
Results
A total of 28 patients were included, of which 14 were + ABR. Preoperative BC-PTA3, sex, age, and number of previous surgeries did not differ significantly between groups (all p > 0.301). Mean postoperative CQ-PTA3 was significantly better for + ABR (1.8 vs. 12.3 dB-HL; p = 0.006). Mean intraoperative ABR threshold was superior for cartilage-counter-bearing and cartilage-housing compared to additional fixation with injectable-platelet-rich- fibrin (53 vs. 56 & 57 dB-HL, respectively; p = 0.04; η2 = 0.33). Mean postoperative BC-PTA3 did not significantly differ between patients (41.4 vs. 41.8 dB-HL; p = 0.77). A total of 7% of the patients required intraoperative readjustment of the FMT based on unsatisfactory intraoperative ABR threshold.
Conclusion
Intraoperative ABR measurement resulted in significantly better postoperative CQ. Cartilage-counter-bearing and cartilage-housing were observed to have superior CQ. A total of 7% of the patients could be spared revision-Vibroplasty due to intraoperative ABR measurement.
Funder
MED-EL Medical Electronics
University of Innsbruck and Medical University of Innsbruck
Publisher
Springer Science and Business Media LLC
Subject
General Medicine,Otorhinolaryngology
Reference25 articles.
1. American Academy of Audiology (2018) The audiologist's guide to hearing aids, personal sound amplification products, hearables, and over-the-counter devices. American Academy of Audiology. Available from https://www.audiology.org/wp-content/uploads/2022/03/Audiologists-Guide-to-OTCs_Updated-March-2022.pdf
2. Beutner D, Delb W, Frenzel H, Hoppe U, Hüttenbrink KB, Mlynski R, Limberger A, Schönweiler R, Schwab B, Todt I, Walger M, Wesarg T, Zahnert T, Zeh R (2018) Guideline “Implantable hearing aids”-short version. HNO 66(9):654–659. https://doi.org/10.1007/s00106-018-0531-4
3. Ball GR (2010) The vibrant soundbridge: design and development. Adv Otorhinolaryngol 69:1–13. https://doi.org/10.1159/000318516
4. Labassi S, Beliaeff M, Péan V, Van de Heyning P (2017) The vibrant soundbridge(®) middle ear implant: a historical overview. Cochlear Implants Int 18(6):314–323. https://doi.org/10.1080/14670100.2017.1358913
5. Dazert S, Shehata-Dieler WE, Dieler R, Helms J (2000) ["Vibrant Soundbridge" middle ear implant for auditory rehabilitation in sensory hearing loss. I. Clinical aspects, indications and initial results]. Laryngorhinootologie 79(8):459–64. DOI: https://doi.org/10.1055/s-2000-5912.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献