Intra- and inter-operator reliability assessment of a novel extramedullary accelerometer-based smart cutting guide for total knee arthroplasty: an in vivo study

Author:

Marcheggiani Muccioli Giulio Maria,Alesi DomenicoORCID,Russo Arcangelo,Lo Presti Mirco,Sassoli Iacopo,La Verde Matteo,Zaffagnini Stefano

Abstract

Abstract Purpose The purpose is to verify the intra- and inter-operator reliability of an extramedullary (EM) accelerometer-based smart cutting guide for distal femoral resection during primary total knee arthroplasty (TKA). The hypothesis of the present study was that the use of the device would result in a good correlation between different operators with a difference between repeated measurements of less than 1°. Methods Twenty-five not consecutive patients with knee osteoarthritis undergone to primary TKA using an EM inertial-based cutting guide to perform distal femoral resection. In order to assess the agreement in femoral axis definition of the device, two operators performed three time each the manoeuvres necessary to define axis. Inter-rater agreement was evaluated with Bland and Altman agreement test. Intra-rater repeatability was evaluated analysing average results distribution of repeated measurements. Accuracy of the device was evaluated comparing differences between intra-operative device data with final implant alignment measured on post-operative longstanding x-rays using Students’ t test. Results Agreement between the two operators was statistically significant (p < 0.05) with a bias of − 0.4° (95% CI − 0.6° to − 0.2°). Average difference between cut orientation measured with device and final implant position, measured on x-rays, was 0.2° (95% CI − 1.5° to 1.7°) with no statistical difference between the two measurements. Final implant alignment, measured on x-ray, was 90.2°, with 95% of cases distributed within range 88.0° to 92.0° for varus-valgus and 2.8° and with 95% of cases distributed within range 2.0° to 4.0° for flexion–extension. Conclusions The EM accelerometer-based smart cutting guide used to perform distal femoral resection during primary TKA demonstrated a good intra- and inter-operator reliability in the present in vivo study.

Funder

Alma Mater Studiorum - Università di Bologna

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3