Abstract
Abstract
Background
In patients with ST-elevation myocardial infarction (STEMI), either with or without cardiogenic shock, mechanical circulatory support with an intra-aortic balloon pump (IABP) is not associated with lower mortality. However, in STEMI patients undergoing urgent coronary artery bypass grafting (CABG), preoperative insertion of an IABP has been suggested to reduce mortality. In this study, the effect of preoperative IABP use on mortality in STEMI patients undergoing urgent CABG was investigated.
Methods
All consecutive STEMI patients undergoing urgent CABG in a single centre between 2000 and 2018 were studied. The primary outcome, 30-day mortality, was compared between patients with and without a preoperative IABP. Subgroup analysis and multivariable analysis using a propensity score and inverse probability treatment weighting were performed to adjust for potential confounders.
Results
A total of 246 patients were included, of whom 171 (69.5%) received a preoperative IABP (pIABP group) and 75 (30.5%) did not (non-pIABP group). In the pIABP group, more patients suffered from cardiogenic shock, persistent ischaemia and reduced left ventricular function. Unadjusted 30-day mortality was comparable between the pIABP and the non-pIABP group (13.3% vs 12.3%, p = 0.82). However, after correction for confounders and inverse probability treatment weighting preoperative IABP was associated with reduced 30-day mortality (relative risk 0.52, 95% confidence interval 0.30–0.88).
Conclusion
In patients with STEMI undergoing urgent CABG, preoperative insertion of an IABP is associated with reduced mortality.
Publisher
Springer Science and Business Media LLC
Reference30 articles.
1. Luca GD, Suryapranata H, Ottervanger JP, Antman EM. Time delay to treatment and mortality in primary angioplasty for acute myocardial infarction. Circulation. 2004;109:1223–5.
2. Gelsomino S, Johnson DM, Lorusso R. Intra-aortic balloon pump: is the tide turning? Crit Care. 2018;22:345.
3. Christenson JT, Simonet F, Badel P, Schmuziger M. Evaluation of preoperative intra-aortic balloon pump support in high risk coronary patients. Eur J Cardiothorac Surg. 1997;11:1097–103.
4. Christenson JT, Simonet F, Schmuziger M. The effect of preoperative intra-aortic balloon pump support in high risk patients requiring myocardial revascularization. J Cardiovasc Surg. 1997;38:397–402.
5. Christenson J, Simonet F, Badel P, Schmuziger M. The effect of preoperative intra-aortic balloon pump support in patients with coronary artery disease, poor left-ventricular function (LVEF <40%), and hypertensive LV hypertrophy. Thorac Cardiovasc Surg. 1997;45:60–4.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献