Background
There is still no reference standard for the implantation of totally implantable venous access ports (TIVAPs). A recently published multicentre randomised controlled trial (RCT) revealed a significantly greater risk of pneumothorax after closed cannulation than after an open strategy. The aim of this meta-analysis was to provide an update of the available evidence for the safety and effectiveness of primary open versus closed cannulation strategy.
Methods
RCTs comparing outcomes of open cut-down of the cephalic vein and closed cannulation of the subclavian vein were sought systematically in MEDLINE, Web of Science and CENTRAL. The primary outcome was the occurrence of pneumothorax. A beta-binominal model was applied to combine the respective outcomes, and results are presented as odds ratios (OR) with 95% confidence interval (CI).
Results
Six RCTs with a total of 1831 patients were included in final analysis. Meta-analysis showed statistically significant superiority of the open cut-down technique regarding pneumothorax (OR 0.308, 95% CI 0.122 to 0.776), but a statistically significant higher failure of the primary technique for the open cut-down technique than for closed cannulation (OR 2.364, 95% CI 1.051 to 5.315). There were no significant differences between the two procedures regarding other morbidity endpoints.
Conclusion
This meta-analysis shows a general superiority of open cut-down of the cephalic vein over closed cannulation of the subclavian vein regarding the occurrence of pneumothorax. Open cut-down should be the first-line approach for TIVAP implantation. Closed cannulation should be performed with ultrasound as second-line procedure if the open technique fails.
Systematic review registration
PROSPERO CRD42013005180
Funder
Bundesministerium für Bildung und Forschung
Publisher
Springer Science and Business Media LLC
Reference42 articles.
1. Niederhuber JE, Ensminger W, Gyves JW, Liepman M, Doan K, Cozzi E (1982) Totally implanted venous and arterial access system to replace external catheters in cancer treatment. Surgery. 92(4):706–712
2. Di Carlo I BRTivadmim-al-tcsMS-VI.
3. Di Carlo I, Pulvirenti E, Mannino M, Toro A (2010) Increased use of percutaneous technique for totally implantable venous access devices. Is it real progress? A 27-year comprehensive review on early complications. Ann Surg Oncol 17(6):1649–1656
4. Tarbiat M, Davoudi M, Salimbahrami SA (2018) Influence of arm position during infraclavicular subclavian vein catheterization in coronary artery bypass graft surgery. J Cardiovas Thor Res 10(4):192–196
5. Increasing the dose intensity of chemotherapy by more frequent administration or sequential scheduling: a patient-level meta-analysis of 37 298 women with early breast cancer in 26 randomised trials. Lancet (London, England). 2019;393(10179):1440-52.