Real-time quantification of laser speckle contrast imaging during intestinal laparoscopic surgery: successful demonstration in a porcine intestinal ischemia model

Author:

Hoffman J. TimORCID,Heuvelings Danique J. I.,van Zutphen Tim,Stassen Laurents P. S.,Kruijff Schelto,Boerma E. Christiaan,Bouvy Nicole D.,Heeman Wido T.,Al-Taher Mahdi

Abstract

Abstract Background Anastomotic leakage (AL) is a dreaded complication following colorectal cancer surgery, impacting patient outcome and leads to increasing healthcare consumption as well as economic burden. Bowel perfusion is a significant modifiable factor for anastomotic healing and thus crucial for reducing AL. Aims The study aimed to calculate a cut-off value for quantified laser speckle perfusion units (LSPUs) in order to differentiate between ischemic and well-perfused tissue and to assess inter-observer reliability. Methods LSCI was performed using a porcine ischemic small bowel loop model with the PerfusiX-Imaging® system. An ischemic area, a well-perfused area, and watershed areas, were selected based on the LSCI colormap. Subsequently, local capillary lactate (LCL) levels were measured. A logarithmic curve estimation tested the correlation between LSPU and LCL levels. A cut-off value for LSPU and lactate was calculated, based on anatomically ischemic and well-perfused tissue. Inter-observer variability analysis was performed with 10 observers. Results Directly after ligation of the mesenteric arteries, differences in LSPU values between ischemic and well-perfused tissue were significant (p < 0.001) and increased significantly throughout all following measurements. LCL levels were significantly different (p < 0.001) at both 60 and 120 min. Logarithmic curve estimation showed an R2 value of 0.56 between LSPU and LCL values. A LSPU cut-off value was determined at 69, with a sensitivity of 0.94 and specificity of 0.87. A LCL cut-off value of 3.8 mmol/L was found, with a sensitivity and specificity of 0.97 and 1.0, respectively. There was no difference in assessment between experienced and unexperienced observers. Cohen’s Kappa values were moderate to good (0.52–0.66). Conclusion Real-time quantification of LSPUs may be a feasible intraoperative method to assess tissue perfusion and a cut-off value could be determined with high sensitivity and specificity. Inter-observer variability was moderate to good, irrespective of prior experience with the technique.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3