Anastomotic perfusion assessment with indocyanine green in robot-assisted low-anterior resection, a multicenter study of interobserver variation

Author:

Larsen Pernille O.ORCID,Nerup Nikolaj,Andersen Jesper,Dohrn Niclas,Klein Mads Falk,Brisling Steffen,Salomon Soren,Andersen Per V.,Möller Soren,Svendsen Morten B. S.,Rahr Hans B.,Iversen Lene H.,Gögenur Ismail,Qvist Niels,Ellebaek Mark B.

Abstract

Abstract Background Securing sufficient blood perfusion to the anastomotic area after low-anterior resection is a crucial factor in preventing anastomotic leakage (AL). Intra-operative indocyanine green fluorescent imaging (ICG-FI) has been suggested as a tool to assess perfusion. However, knowledge of inter-observer variation among surgeons in the interpretation of ICG-FI is sparse. Our primary objective was to evaluate inter-observer variation among surgeons in the interpretation of bowel blood-perfusion assessed visually by ICG-FI. Our secondary objective was to compare the results both from the visual assessment of ICG and from computer-based quantitative analyses of ICG-FI between patients with and without the development of AL. Method A multicenter study, including patients undergoing robot-assisted low anterior resection with stapled anastomosis. ICG-FI was evaluated visually by the surgeon intra-operatively. Postoperatively, recorded videos were anonymized and exchanged between centers for inter-observer evaluation. Time to visibility (TTV), time to maximum visibility (TMV), and time to wash-out (TWO) were visually assessed. In addition, the ICG-FI video-recordings were analyzed using validated pixel analysis software to quantify blood perfusion. Results Fifty-five patients were included, and five developed clinical AL. Bland–Altman plots (BA plots) demonstrated wide inter-observer variation for visually assessed fluorescence on all parameters (TTV, TMV, and TWO). Comparing leak-group with no-leak group, we found no significant differences for TTV: Hazard Ratio; HR = 0.82 (CI 0.32; 2.08), TMV: HR = 0.62 (CI 0.24; 1.59), or TWO: HR = 1.11 (CI 0.40; 3.11). In the quantitative pixel analysis, a lower slope of the fluorescence time-curve was found in patients with a subsequent leak: median 0.08 (0.07;0.10) compared with non-leak patients: median 0.13 (0.10;0.17) (p = 0.04). Conclusion The surgeon’s visual assessment of the ICG-FI demonstrated wide inter-observer variation, there were no differences between patients with and without AL. However, quantitative pixel analysis showed a significant difference between groups. Trial Registration ClinicalTrials.gov Identifier: NCT04766060.

Publisher

Springer Science and Business Media LLC

Subject

Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3