Abstract
AbstractWeathered basement aquifers are vital sources of drinking water in Africa. In order to better understand their role in the urban water balance, in a weathered basement aquifer in Kampala, Uganda, this study installed a transect of monitoring piezometers, carried out spring flow and high-frequency groundwater level monitoring, slug tests and hydrochemical analyses, including stable isotopes and groundwater residence time indicators. Findings showed a typical weathered basement aquifer with a 20–50-m thickness. Groundwater recharge was 3–50 mm/year, occurring during sustained rainfall. Recharge to a deep groundwater system within the saprock was slow and prolonged, while recharge to the springs on the valley slopes was quick and episodic, responding rapidly to precipitation. Springs discharged shallow groundwater, mixed with wastewater infiltrating from onsite sanitation practices and contributions from the deeper aquifer and were characterised by low flow rates (< 0.001 m3/s), low pH (<5), high nitrate values (61–190 mg/L as NO3), and residence times of <30 years. The deeper groundwater system occurred in the saprolite/saprock, had low transmissivity (< 1 × 10−5 m2/s), lower nitrate values (<20 mg/L as NO3), pH 6–6.5 and longer residence times (40–60 years). Confined groundwater conditions in the valleys were created by the presence of clay-rich alluvium and gave rise to artesian conditions where groundwater had lower nitrate concentrations. The findings provide new insights into weathered basement aquifers in the urban tropics and show that small-scale abstractions are more sustainable in the deeper groundwater system in the valleys, where confined conditions are present.
Publisher
Springer Science and Business Media LLC
Subject
Earth and Planetary Sciences (miscellaneous),Water Science and Technology
Reference112 articles.
1. Acworth RI (1981) The evaluation of groundwater resources in the crystalline basement of northern Nigeria. PhD Thesis, University of Birmingham, UK. https://etheses.bham.ac.uk/id/eprint/3576/. Accessed 22 Feb 2022
2. Alle IC, Descloitres M, Vouillamoz JM, Yalo N, Lawson FMA, Adihou AC (2018) Why 1D electrical resistivity techniques can result in inaccurate siting of boreholes in hard rock aquifers and why electrical resistivity tomography must be preferred: the example of Benin, West Africa. J Afr Earth Sci 139:341–353. https://doi.org/10.1016/J.JAFREARSCI.2017.12.007
3. Babar M (2007) Environmental changes and natural disasters. In: Sawant PT, Sathe NJ (eds) Influence of lineaments on landslide prone area around Mahad Raigad District Maharashtra. New India Publishing Agency, New Delhi, pp 197–213
4. Banks EW, Cook PG, Owor M, Okullo J, Kebede S, Nedaw D, Mleta P, Fallas H, Gooddy D, MacAllister DJ, Mkandawire T (2021) Environmental tracers to evaluate groundwater residence times and water quality risk in shallow unconfined aquifers in sub Saharan Africa. J Hydrol 598. https://doi.org/10.1016/j.jhydrol.2020.125753
5. Barrett MH, Hiscock KM, Pedley S, Lerner DN, Tellam JH, French MJ (1999) Marker species for identifying urban groundwater recharge sources: a review and case study in Nottingham, UK. Water Res 33:3083–3097
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献