Suture material choice can increase risk of hypersensitivity in hand trauma patients

Author:

Koppa Mayank,House Rosemary,Tobin Vicky,Rozen Warren M.,Hunter-Smith David J.,Goldie Stephen J.

Abstract

Abstract Introduction Hypersensitivity is an unfortunate potential outcome in patients undergoing surgery following traumatic injuries to their hands. In our practice, we noted that certain suture types may increase the risk of the patient developing hypersensitivity. Methodology We conducted a retrospective observational study to investigate if certain suture materials increase the risk of hypersensitivity when used to repair surgical wounds in hand trauma. Patients undergoing hand trauma surgery over a period of five consecutive months were included in the study. Ethics committee approval was obtained from Peninsula Health’s research office. Results 184 patients were included in the study. Hypersensitivity was observed in 30 (16.3%) patients post-operatively. Chromic gut suture was used in 53.3% of the patients who experienced hypersensitivity. Patients who had chromic catgut used in their surgery were 2.82 times more likely to develop hypersensitivity than patients who did not have chromic gut used (p = 0.0015). If a patient had a nerve repaired and chromic gut sutured used, they were 6.50 times more likely to develop hypersensitivity (p < 0.0001). Conclusion Surgeons should be aware that this data indicates that suture choice in hand trauma patients can greatly impact the risk of the patient developing hypersensitivity. Level of evidence: Level IV, risk/prognostic study.

Funder

Flinders University

Publisher

Springer Science and Business Media LLC

Subject

Surgery

Reference6 articles.

1. Packham TL, MacDermid JC, Michlovitz S, Cup E, Van de Ven-Stevens L (2018) Cross cultural adaptation and refinement of an English version of a Dutch patient-reported questionnaire for hand sensitivity: the Radboud evaluation of sensitivity. J Hand Ther 31:371–380

2. Bharathi A, Reddy DBD, Kote GSS (2013) A prospective randomized comparative study of vicryl rapide versus chromic catgut for episiotomy repair. J Clin Diagn Res 7:326–330

3. Engler RJ, Weber CB, Turnicky R (1986) Hypersensitivity to chromated catgut sutures: a case report and review of the literature. Ann Allergy 56:317–320

4. Bennett RA, Yaeger MJ, Trapp A, Cambre RC (1997) Histologic evaluation of the tissue reaction to five suture materials in the body wall of rock doves (Columba livia). J Avian Med Surg 11:175–182

5. Vaksvik T, Røkkum M, Holm I (2018) Cold hypersensitivity after hand injuries. A prospective 7-year follow-up. J Plas Surg Hand Surg 52:363–366