Abstract
AbstractThe use of engineered wood products and mass timber panels such as cross laminated timber (CLT), glued laminated timber (glulam) and laminated veneer lumber (LVL) is becoming more common, as these products have benefits in terms of environmental credentials and resource utilisation and have the potential to provide faster and more economical construction processes. However, timber exposed to moisture for prolonged periods can degrade biologically, leading to a loss of appearance and decreased mechanical properties. Southern pine, radiata pine and shining gum timber are important forest resources for the Australian timber industry. To date, no in-depth studies on the hygroscopic properties of these species have been carried out from a timber wetting point of view. Consequently, existing literature has a knowledge gap regarding the determination of moisture movement properties in these species that are applicable to numerical modelling when used as solid wood or in the production of engineered wood products (EWPs). The work presented herein will help develop a better understanding of moisture ingress and egress in solid timber and EWPs and provide data for future predictive tools (such as numerical modelling) for moisture management in timber buildings. Samples were prepared from solid timber as well as EWP’s to examine the relationships between glue lines and edge gaps in CLT and multiple glue lines in LVL on moisture movement. As expected, longitudinal permeability was higher than radial and tangential permeability for the species tested. Southern pine samples had higher gas and liquid permeability values than radiata pine and shining gum. CLT with end grain sections including an edge gap had higher gas and liquid permeability than similar sections with glue lines only. LVL sections with 1 glue line had slightly lower permeability values than in samples with 2 glue lines. Gas and liquid permeabilities were lower for LVL samples than a two-layered veneer section without a glue line illustrating the barrier posed by the glue line. The moisture loss parameter during the diffusion testing was higher for LVL ends and CLT ends with edge gaps than face and edge sample sections. The results will be used to develop numerical models for moisture behaviour in solid and composite timber panels when exposed to humidity and free water. It is recommended to conduct additional studies to examine the impact of the adhesive layer and its properties on impeding moisture migration or functioning as a moisture barrier.
Funder
The National Centre for Timber Durability and Design Life
State of Queensland acting through the Department of Agriculture and Fisheries
Publisher
Springer Science and Business Media LLC
Subject
General Materials Science,Forestry
Reference52 articles.
1. Agoua E, Zohoun S, Perré P (2001) A double climatic chamber used to measure the diffusion coefficient of water in wood in unsteady-state conditions: determination of the best fitting method by numerical simulation. Int J Heat Mass Transf 44(19):3731–3744
2. Australia S (2016) "AS/NZS 1080.3:2000 timber—methods of test, method 3: density", intertek SAI Global Standards Legislation. https://infostore.saiglobal.com/en-us/standards/AS-NZS-1080-3-2000-117874_SAIG_AS_AS_246811/. Accessed Apr 2022
3. Beebe K, Kam-Biron M (2016) Five Ds of moisture management: deflection, drainage, drying, distance, and durable materials. In: Proceedings of the SEAC. Maui, Hawaii, USA. The Engineered Wood Association
4. Brischke C, Alfredsen G (2020) Wood-water relationships and their role for wood susceptibility to fungal decay. Appl Microbiol Biotechnol 104(9):3781–3795
5. Bucklin O, Menges A, Amtsberg F, Drexler H, Rohr A, Krieg OD (2022) Mono-material wood wall: novel building envelope using subtractive manufacturing of timber profiles to improve thermal performance and airtightness of solid wood construction. Energy Build 254:111597
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献