Abstract
AbstractTwo full-scale building specimens were tested on the shake-table at the EUCENTRE Foundation laboratories in Pavia (Italy), to assess the effectiveness of an innovative timber retrofit solution, within a comprehensive research campaign on the seismic vulnerability of existing Dutch unreinforced masonry structures. The buildings represented the end-unit of a two-storey terraced house typical of the North-Eastern Netherlands, a region affected by induced seismicity over the last few decades. This building typology is particularly vulnerable to earthquake excitation due to lack of seismic details and irregular distribution of large openings in masonry walls. Both specimens were built with the same geometry. Their structural system consisted of cavity walls, with interior load-bearing calcium-silicate leaf and exterior clay veneer, and included a first-floor reinforced concrete slab, a second-floor timber framing, and a roof timber structure supported by masonry gables. A timber retrofit was designed and installed inside the second specimen, providing an innovative sustainable, light-weight, reversible, and cost-effective technique, which could be extensively applied to actual buildings. Timber frames were connected to the interior surface of the masonry walls and completed by oriented strands boards nailed to them. The second-floor timber diaphragm was stiffened and strengthened by a layer of oriented-strand boards, nailed to the existing joists and to additional blocking elements through the existing planks. These interventions resulted also in improved wall-to-diaphragm connections with the inner leaf at both floors, while steel ties were added between the cavity-wall leaves. The application of the retrofit system favored a global response of the building with increased lateral capacities of the masonry walls. This paper describes in detail the bare and retrofitted specimens, compares the experimental results obtained through similar incremental dynamic shake-table test protocols up to near-collapse conditions, and identifies damage states and damage limits associated with displacements and deformations.
Funder
Università degli Studi di Pavia
Publisher
Springer Science and Business Media LLC
Subject
Geophysics,Geotechnical Engineering and Engineering Geology,Building and Construction,Civil and Structural Engineering
Reference54 articles.
1. American Wood Council (AWC) (2008) ANSI/AF&PA SDPWS-2008: special design provisions for wind and seismic. Washington, DC, USA
2. Arias A (1970) A measure of earthquake intensity. In: Hansen RJ (ed) Seismic design of nuclear power plants, 1st edn. MIT Press, Cambridge, pp 438–483
3. Arslan O, Messali F, Smyrou E, Bal İE, Rots JG (2020) Experimental characterization of the axial behavior of traditional masonry wall metal tie connections in cavity walls. Constr Build Mater. https://doi.org/10.1016/j.conbuildmat.2020.121141
4. Arup (2020) Exposure Database V7 Data Documentation, Arup report 229746_031.0_REP2015, ARUP, Amsterdam, The Netherlands. https://nam-onderzoeksrapporten.data-app.nl/reports/download/groningen/en/b0b54c89-45d5-4765-8843-6c79903a0ef8
5. Bianchini M, Diotallevi P, Baker JW (2009) Prediction of inelastic structural response using an average of spectral accelerations. In: Proceedings of the 10th international conference on structural safety and reliability (ICOSSAR09), Osaka, Japan
Cited by
36 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献