Taylor spatial frame in the treatment of neglected fractures

Author:

Al-Sayyad Mohammed J.1

Affiliation:

1. Department Orthopedic Surgery, King Abdulaziz University Hospital, P.O. Box 1817, 21441, Jeddah Saudi Arabia

Abstract

Background The Taylor spatial frame (TSF, Smith and Nephew, Memphis, TN, USA) is a modern multiplanar external fixator that combines ease of application and computer accuracy. Many patients in our geographic area seek treatment for their fractures by traditional bonesetters and present in the middle of treatment with neglected malaligned fractures. These fractures were an average of 10 weeks old (range 6–14 weeks) fractures with callus that were allowed to heal in a poor position. The spatial frame is applied easily on the fracture bone fragments. The accuracy of fracture reduction and deformity correction is dependant on analyzing anteroposterior and lateral radiographs of the fracture. Our experience with this external fixator in the treatment of neglected fractures is summarized. Method Over a period of 6 years, the TSF was used in 24 neglected fracture cases which were collected from our prospective external fixator data base. All cases were followed for a minimum of 3 years. The data base and radiographs were reviewed in order to obtain demographic data, malalignment parameters, final correction, time in the TSF, and complications. Result The patients’ ages ranged from 6 to 18 years. All were neglected fractures. The average delay in treatment was 10 weeks (range 6–14 weeks). All patients had closed osteoclasis. The time spent in the TSF varied according to the patient age and bone involved. Ten femoral and 14 tibial fractures were included. Ten patients had superficial pin site infections that resolved with oral antibiotics. Postoperatively, no patient was noted to be more than 5° malrotated on clinical examination and no functional leg length discrepancy was observed. All of the fractures united. Conclusion Anatomic alignment was achieved in all tibial fracture patients. At the final follow-up, fracture angulation and shortening were fully corrected, and some translational malalignment persisted in 67% of femur fractures. The TSF is an effective definitive method for the treatment of neglected fractures. Level of evidence IV.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Pediatrics, Perinatology and Child Health

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3