Abstract

Abstract Objectives Currently, there is no standardized measurement method for evaluating cup overhang (CO) in patients undergoing total hip arthroplasty (THA). We propose a novel, standardized method of measuring overhang distance in patients following primary total hip arthroplasty (THA) on computed tomography (CT) images after multiplanar reformation and compare it to a previously proposed measurement method on sagittal CT images. Materials and methods This retrospective study included patients who underwent primary THA with an anterior approach. Patients with cup overhang (CO) and iliopsoas impingement (IPI) were identified by clinical and imaging data. Uncorrected overhang distance (ODu) was evaluated on orthogonal sagittal CT images while corrected overhang distance (ODc) was evaluated on reformatted sagittal CT images corrected for pelvic rotation and aligned with the plane of the cup face. Results Out of 220 patients with THA, 23 patients (10.4%) with CO and 16 patients (7.3%) with IPI were identified. CO was significantly associated to IPI (p < 0.001). The inter- and intrareader agreement was almost perfect for ODc (κ = 0.822, κ = 0.850), whereas it was fair and moderate for ODu (κ = 0.391, κ = 0.455), respectively. The discriminative ability of ODc was excellent (area under the curve (AUC) = 0.909 (95% confidence interval (CI) 0.784–1.000)) in the receiver operating characteristic analysis. Conversely, AUC for ODu was poor, measuring 0.677 (95% CI 0.433–0.921). Conclusion We implemented a novel measurement method for CT images reformatted at the plane of the cup face to assess overhang distance in patients with CO following THA. Clinical relevance statement While further validation is necessary, the proposed method is characterized by its high reproducibility and might be used to predict the occurrence of iliopsoas impingement in patients with cup overhang following total hip arthroplasty. Key Points A novel, standardized method of measuring cup overhang distance in patients following primary total hip arthroplasty on CT images is proposed. Cup overhang was associated to iliopsoas impingement. The proposed method was reproducible and showed excellent prediction of iliopsoas impingement in patients with cup overhang. This method can be implemented in clinical practice when assessing CT images of patients with cup overhang for iliopsoas impingement.

Funder

University of Zurich

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3