Abstract
Abstract
Objective
Impact of different MR perfusion software on selection and outcome of patients with acute ischemic stroke (AIS) and large vessel occlusion (LVO) treated by endovascular thrombectomy (EVT) is unclear. We aimed at comparing two commercial MRI software, semi-automated with unadjusted (method A) and adjusted mask (method B), and fully automated (method C) in this setting.
Methods
MRI from 144 consecutive AIS patients with anterior circulation LVO was retrospectively analysed. All diffusion- and perfusion-weighted images (DWI-PWI) were post-processed with the three methods using standard thresholds. Concordance for core and hypoperfusion volumes was assessed with Lin’s test. Clinical outcome was compared between groups in patients who underwent successful EVT in the early and late time window.
Results
Mean core volume was higher and mean hypoperfusion volume was lower in method C than in methods A and B. In the early time window, methods A and B found fewer patients with a mismatch ratio ≤ 1.2 than method C (1/67 [1.5%] vs. 12/67 [17.9%], p = 0.0013). In the late time window, methods A and B found fewer patients with a mismatch ratio < 1.8 than method C (3/46 [6.5%] and 2/46 [4.3%] vs. 18/46 [39.1%], p ≤ 0.0002). More patients with functional independence at 3 months would not have been treated using method C versus methods A and B in the early (p = 0.0063) and late (p ≤ 0.011) time window.
Conclusions
MRI software for DWI-PWI analysis may influence patients’ selection before EVT and clinical outcome.
Key Points
• Method C detects fewer patients with favourable mismatch profile.
• Method C might underselect more patients with functional independence at 3 months.
• Software used before thrombectomy may influence patients’ outcome.