Abstract
Objectives
To describe persistent nephrographic patterns detected by unenhanced renal CT at 24 h after cardiac catheterisation and intervention.
Methods
This prospective study was Health Insurance Portability and Accountability Act-compliant and institutional review board approved. Twenty-nine patients (20 men, nine women; average age 63.27 and range 41–85 years) agreed to undergo unenhanced dual-energy computed tomography (CT) limited to their kidneys at 24 h after cardiac catheterisation. CT attenuation values (Hounsfield units) were made from the cortical and medullary regions and single kidney total parenchymal iodine values (milligrams) were measured. Spearman’s rank correlation coefficient and a two-sided Fisher’s exact test were used in the statistics.
Results
Focal nephrograms were observed in at least one kidney (range, one to five regions per kidney) in 10/29 (34%) of patients and bilateral global nephrograms in 13/29 (45%) of patients. Focal nephrograms correlated with cardiac catheterisation fluoroscopic time (r = 0.48; P = 0.0087). For global nephrograms, the total iodine content of right and left kidneys correlated with fluoroscopic time (r = 0.79 and 0.76; P < 0.0001, respectively) and the amount of contrast material (CM) used (r = 0.77 and r = 0.74; P < 0.0001, respectively).
Conclusion
Persistent focal and global nephrograms occur commonly as assessed by non-contrast CT at 24 h post cardiac catheterisation and our observations suggest they could be related to procedural factors.
Publisher
Springer Science and Business Media LLC
Subject
Radiology Nuclear Medicine and imaging
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献