Non-contact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates

Author:

Maurya Lalit,Zwiggelaar Reyer,Chawla Deepak,Mahapatra Prasant

Abstract

AbstractRespiratory rate (RR) monitoring is essential in neonatal intensive care units. Despite its importance, RR is still monitored intermittently by manual counting instead of continuous monitoring due to the risk of skin damage with prolonged use of contact electrodes in preterm neonates and false signals due to displacement of electrodes. Thermal imaging has recently gained significance as a non-contact method for RR detection because of its many advantages. However, due to the lack of information in thermal images, the selection and tracking of the region of interest (ROI) in thermal images for neonates are challenging. This paper presents the integration of visible (RGB) and thermal (T) image sequences for the selection and tracking of ROI for breathing rate extraction. The deep-learning based tracking-by-detection approach is employed to detect the ROI in the RGB images, and it is mapped to the thermal images using the RGB-T image registration. The mapped ROI in thermal spectrum sequences gives the respiratory rate. The study was conducted first on healthy adults in different modes, including steady, motion, talking, and variable respiratory order. Subsequently, the method is tested on neonates in a clinical settings. The findings have been validated with a contact-based reference method.The average absolute error between the proposed and belt-based contact method in healthy adults reached 0.1 bpm and for more challenging conditions was approximately 1.5 bpm and 1.8 bpm, respectively. In the case of neonates, the average error is 1.5 bpm, which are promising results. The Bland–Altman analysis showed a good agreement of estimated RR with the reference method RR and this pilot study provided the evidence of using the proposed approach as a contactless method for the respiratory rate detection of neonates in clinical settings.

Funder

Commonwealth Split Site Scholarship

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine,Health Informatics

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3