Added value of zoomed-echo-planar imaging diffusion-weighted imaging for evaluation of periampullary carcinomas

Author:

Liu JingjingORCID,Huang Mengyue,Ren Yanan,Xu Man,Zhu Jinxia,Li Yinhua,Cheng Jingliang

Abstract

Abstract Background To assess the image quality feasibility and diagnostic value of zoomed diffusion-weighted imaging (z-EPI DWI) using echo-planar imaging (EPI) compared with conventional DWI (c-EPI DWI) in patients with periampullary disease. Methods Thirty-six patients with periampullary carcinomas and fifteen with benign periampullary disease were included in this study. All the subjects underwent MR cholangiopancreatography (MRCP), c-EPI DWI, and z-EPI DWI. Two radiologists independently assessed image quality of the two image sets, including overall image quality and lesion conspicuity. In addition, signal intensity and ADC measurements of DWIs in the periampullary lesions were conducted. Diagnostic accuracies of the combined image sets of MRCP and z-EPI DWI were compared with those of a combined set of MRCP and c-EPI DWI. Results z-EPI DWI showed significantly better image quality scores (anatomic structure visualization, 2.94 ± 0.24; overall image quality, 2.96 ± 0.17) compared to that with c-EPI DWI (anatomic structure visualization, 2.02 ± 0.22; overall image quality, 2.04 ± 0.24) (both P < 0.01). For all the periampullary malignant lesions and small lesions (≤ 20 mm), there was better delineation of lesion conspicuity and the lesion margin, as well as diagnostic confidence with z-EPI DWI (all P < 0.05). The rate of periampullary malignancy’s hyperintense signal on z-EPI DWI was increased to 91.7% (33/36) compared to c-EPI DWI (69.4% (25/36)) (P = 0.023). For all malignant lesions and small lesions, the diagnostic accuracy scores were increased using the MRCP and z-EPI DWI combined set, compared to the MRCP and c-EPI DWI combined set (P < 0.05). Diagnostic accuracy for detection and differentiation of malignant lesions from benign lesions significantly improved for the MRCP and z-EPI DWI combined set compared with MRCP and c-EPI DWI combined set (P < 0.05). There were no significant differences between c-EPI DWI and z-EPI DWI in the ADC values of periampullary malignant and benign lesions (P > 0.05). Conclusions z-EPI DWI has an advantage that could lead to remarkable image quality improvements and enhanced lesion visualization of periampullary carcinomas. z-EPI DWI was superior to c-EPI DWI for detecting, delineating, and diagnosing the lesions, particularly for small challenging lesions. Graphical abstract

Funder

the Medical Science and Technology Project of Henan Province

Publisher

Springer Science and Business Media LLC

Subject

Urology,Gastroenterology,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3