Diagnostic reference levels for chest computed tomography in children as a function of patient size

Author:

Bos DeniseORCID,Zensen Sebastian,Opitz Marcel K.,Haubold Johannes,Nassenstein Kai,Kinner Sonja,Schweiger Bernd,Forsting Michael,Wetter Axel,Guberina Nika

Abstract

Abstract Background Radiation exposures from computed tomography (CT) in children are inadequately studied. Diagnostic reference levels (DRLs) can help optimise radiation doses. Objective To determine local DRLs for paediatric chest CT performed mainly on modern dual-source, multi-slice CT scanners as a function of patient size. Materials and methods Five hundred thirty-eight chest CT scans in 345 children under 15 years (y) of age (median age: 8 y, interquartile range [IQR]: 4–13 y) performed on four different CT scanners (38% on third-generation and 43% on second-generation dual-source CT) between November 2013 and December 2020 were retrospectively analysed. Examinations were grouped by water-equivalent diameter as a measure of patient size. DRLs for volume CT dose index (CTDIvol) and dose-length product (DLP) were determined for six different patient sizes and compared to national and European DRLs. Results The DRLs for CTDIvol and DLP are determined for each patient size group as a function of water-equivalent diameter as follows: (I) < 13 cm (n = 22; median: age 7 months): 0.4 mGy, 7 mGy·cm; (II) 13 cm to less than 17 cm (n = 151; median: age 3 y): 1.2 mGy, 25 mGy·cm; (III) 17 cm to less than 21 cm (n = 211; median: age 8 y): 1.7 mGy, 44 mGy·cm; (IV) 21 cm to less than 25 cm (n = 97; median: age 14 y): 3.0 mGy, 88 mGy·cm; (V) 25 cm to less than 29 cm (n = 42; median: age 14 y): 4.5 mGy, 135 mGy·cm; (VI) ≥ 29 cm (n = 15; median: age 14 y): 8.0 mGy, 241 mGy·cm. Compared with corresponding age and weight groups, our size-based DRLs for DLP are 54% to 71% lower than national and 23% to 85% lower than European DRLs. Conclusion We developed DRLs for paediatric chest CT as a function of patient size with substantially lower values than national and European DRLs. Precise knowledge of size-based DRLs may assist other institutions in further dose optimisation in children.

Funder

Universitätsklinikum Essen

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Pediatrics, Perinatology and Child Health

Reference31 articles.

1. European Commission (2018) Radiation Protection N° 185 - European guidelines on diagnostic reference levels for paediatric imaging. European Commission, Luxembourg: Publications Office of the European Union

2. International Commission on Radiological Protection (1991) 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP 21:1–201

3. European Commission (1997) COUNCIL DIRECTIVE 97/43/EURATOM of 30 June 1997 on health protection of individuals against the dangers of ionising radiation in relation to medical exposure, and repealing Directive 84/466/Euratom. Off J Eur Commun L 180(09):07

4. European Council Directive 2013/59/Euratom on basic safety standards for protection against the dangers arising from exposure to ionising radiation and repealing Directives 89/618/Euratom, 90/641/Euratom, 96/29/Euratom, 97/43/Euratom and 2003/122/Euratom (2014) Official Journal of the European Union. L13; 57: 1–73

5. National Radiological Protection Board (1999) Guidelines on patient dose to promote the optimisation of protection for diagnostic medical exposures, Report of an Advisory Group on Ionising Radiation. NRPB Vol 10, No 1, Chilton, Didcot, Oxon OX11 ORQ, UK, ISBN 0–85951–425–0

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Assessing Effective Doses and Proposing DRLs for Pediatric CT Procedures in Madinah (Single Hospital), Saudi Arabia;Applied Sciences;2024-08-27

2. Age-based diagnostic reference levels and achievable doses for paediatric CT: a survey in Shanghai, China;Journal of Radiological Protection;2024-04-23

3. Radiation exposure in computed tomography;Deutsches Ärzteblatt international;2023-03-03

4. Analysis of Indonesia regional radiation dose profile for general radiography and CT-scan;CHEMISTRY BEYOND BORDERS: INTERNATIONAL CONFERENCE ON PHYSICAL CHEMISTRY: The 1st Annual Meeting of the Physical Chemistry Division of the Indonesian Chemical Society;2023

5. Pediatric diagnostic reference level for chest procedure in general radiography: A study in Indonesia;CHEMISTRY BEYOND BORDERS: INTERNATIONAL CONFERENCE ON PHYSICAL CHEMISTRY: The 1st Annual Meeting of the Physical Chemistry Division of the Indonesian Chemical Society;2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3