Abstract

Background: Computed tomography angiography (CTA) is the reference technique for the measurement of native maximum abdominal aortic aneurysm (AAA) diameter when surgery is being considered. However, there is a wide choice available for the methodology of maximum AAA diameter measurement on CTA, and to date, no consensus has been reached on which method is best. We analyzed clinical decisions based on these various measures of native maximum AAA diameter with CTA, then analyzed their reproducibility and identified the method of measurement yielding the highest agreement in terms of patient management. Materials and Methods: Three sets of measures in 46 native AAA were obtained, double-blind by three radiologists (J, S, V) on orthogonal planes, curved multiplanar reconstructions, and semi-automated-software, based on the AAA-lumen centerline. From each set, the clinical decision was recorded as follows: "Follow-up" (if all diameters <50 mm), "ambiguous" (if at least one diameter <50 mm AND at least one ≥50 mm) or "Surgery " (if all diameters ≥50 mm). Intra- and interobserver agreements in clinical decisions were compared using the weighted Kappa coefficient. Results: Clinical decisions varied according to the measurement sets used by each observer, and according to intra and interobserver (lecture#1) reproducibility. Based on the first reading of each observer, the number of AAA proposed for surgery ranged from 11 to 24 for J, 5 to 20 for S, and 15 to 23 for V. The rate of AAAs classified as "ambiguous" varied from 11% (5/46) to 37% (17/46).The semi-automated method yielded very good intraand interobserver agreements in clinical decisions in all comparisons (Kappa range 0.83–1.00). Conclusion: The semi-automated method seems to be appropriate for native AAA maximum diameter measurement on CTA. In the absence of AAA outer-wallbased software more robust for complex AAA, clinical decisions might best be made with diameter values obtained using this technique.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3