UNIPOLAR VERSUS BIPOLAR HEMIARTHROPLASTY IN ELDERLY PATIENTS WITH FRACTURE NECK OF FEMUR

Author:

Gupta Parag1,Patel Zeel2,Jha Ashish3,Anbalagan Praveen4,Sharma Gaurav5,Kadam Rahul6

Affiliation:

1. unior Resident, Department of Orthopedics, MGM Medical College and Hospital, Navi Mumba

2. Junior Resident, Department of Orthopedics, MGM Medical College and Hospital, Navi Mumba

3. Junior Resident, Department of Orthopedics, MGM Medical College and Hospital, Navi Mumbai

4. Senior Resident, Department of Orthopedics, MGM Medical College and Hospital, Navi Mumbai

5. Assistant Professor, Department of Orthopedics, MGM Medical College and Hospital, Navi Mumbai

6. Professor, Department of Orthopedics, MGM Medical College and Hospital, Navi Mumba

Abstract

Background/Purpose: Hemiarthroplasty is the treatment of choice n neck of femur fractures in elderly patients. Unipolar and bipolar prostheses have their own advantages and disadvantages, creating confusion in which prothesis to use. 40 elderly patients (>65 years age) with intracaps Methods: ular neck of femur fractures were included and randomly divided equally in this study, 20 patients were treated with unipolar hemiarthroplasty and 20 patients with bipolar hemiarthroplasty. All patients were evaluated for functional outcome by using Harris Hip score and radiological outcomes using various parameters. The outcomes of both groups were then compared using Chi-square test. Results: Overall mean Harris hip score pre operatively for unipolar hemiarthroplasty was 36.2 and bipolar hemiarthroplasty was 39.1 which increased to 81.8 for unipolar and 85.05 for bipolar hemiarthroplasty respectively, with p-value of <0.561. Our results also shows that we have 35% excellent result in Bipolar whereas we have 15% excellent result in unipolar Hemiarthroplasty group. The results of our study shows that uncemented bipolar hemiarthroplasty Conclusion: gave better results when compared with uncemented unipolar hemiartheoplasty. Our results also shows that, cemented bipolar hemiarthroplasty gave better results when compared with cemented unipolar hemiarthroplasty clinically and radiologically. Thus, Bipolar hemiarthroplasty did better when compared with unipolar hemiarthroplasty in general

Publisher

World Wide Journals

Subject

Earth and Planetary Sciences (miscellaneous),Computers in Earth Sciences,Computer Science Applications,Engineering (miscellaneous),Earth and Planetary Sciences (miscellaneous),Instrumentation,Geography, Planning and Development,Visual Arts and Performing Arts,Communication,Cultural Studies,Visual Arts and Performing Arts,Cultural Studies,Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Atomic and Molecular Physics, and Optics,Software,Atomic and Molecular Physics, and Optics,Electronic, Optical and Magnetic Materials,Dermatology,Surgery,Electrical and Electronic Engineering,Hardware and Architecture,Condensed Matter Physics,Atomic and Molecular Physics, and Optics,Electronic, Optical and Magnetic Materials,Electronic, Optical and Magnetic Materials,Cell Biology,Plant Science,Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3